Process Data Sheet

EOS CopperAlloy CuCrZr for EOS M 400 | 80 µm

EOS M 400 - 80 µm - TRL 5

System Setup EOS M 400
EOS Material set CuCrZr_080_CoreM400
Software Requirements

EOSPRINT 2.11 or newer

EOSYSTEM 2.15 or newer

Recoater Blade HSS (High Speed Steel)
Inert gas Argon
Sieve 90 µm
Additional Information
Layer Thickness 80 µm
Volume Rate 10.9 mm³/s
Min. Wall Thickness 0.8 mm

Chemical and Physical Properties of Parts

Solid parts chemistry matches the powder chemistry

Etched micrograph

Microstructure of the Produced Parts

Defects Thickness Result Number of Samples
Average Defect Percentage 80 µm 0.2 % -
Density EN ISO 3369 Thickness Result Number of Samples
Average Density 80 µm ≥ 8.84 g/cm³ -

Mechanical Properties

Mechanical Properties Heat Treated

EN ISO 6892-1 Room Temperature | Yield Strength [MPa] Tensile Strength [MPa] Elongation at Break A [%] Reduction of Area Z [%] Modulus of elasticity [GPa] Number of Samples
Vertical 230 350 36 69 115 -
Horizontal 255 410 30 63 130 -

Conductivity optimized heat treatment

Mechanical Properties Heat Treated

EN ISO 6892-1 Room Temperature | Yield Strength [MPa] Tensile Strength [MPa] Elongation at Break A [%] Reduction of Area Z [%] Modulus of elasticity [GPa] Number of Samples
Vertical 495 540 18 49 125 -
Horizontal 510 590 18 45 120 -

Tensile properties optimsed heat treatment 

Modulus of elasticity testing according to EN ISO 6892-1 Method A, Range 1 (0.00007 1/s).

Hardness

Heat Treated
Value 120
Unit HV10

Conductivity optimized heat treatment 

Heat Treated
Value 190
Unit HV10

Tensile properties optimized heat treatment 

Surface Roughness

Electrical Conductivity

ASTM E1004-17 Orientation Typical Electrical Conductivity [%IACS]
Heat Treated | 80 µm | Default Vertical 88

Conductivity optimized heat treatment 
2 sample cubes, all measured from 5 surfaces. Standard deviation 3.0

ASTM E1004-17 Orientation Typical Electrical Conductivity [%IACS]
Heat Treated | 80 µm | Default Vertical 76

Tensile properties optimzed heat treatment. 3 sample cubes, all measured from 5 surfaces. Standard deviation 0.7

ASTM E1004-17 Orientation Typical Electrical Conductivity [%IACS]
Heat Treated | 80 µm | Default Vertical 85

DAH conductivity heat treatment. 1 sample cubes, all measured from 5 surfaces. Standard deviation 0.7

ASTM E1004-17 Orientation Typical Electrical Conductivity [%IACS]
As Manufactured | 80 µm | Default Vertical 23
Generate und open PDF