Process Information Polymer
PA 2200 CarbonReduced Balance
Product Description
The advantage of the process parameter Balance, at 120µm layer thickness, lies in its ability to balance different factors at the same time, e.g., production costs, mechanical properties, surface quality and accuracy. Therefore it is suitable for parts with varying geometries, dimensions and requirements.
| MECHANICAL PROPERTIES | DRY / CONDITIONED | UNIT | TEST STANDARD | DRY / CONDITIONED | UNIT | TEST STANDARD |
|---|---|---|---|---|---|---|
|
Tensile Modulus X Orientation Y Orientation Z Orientation |
1650 / - 1650 / - 1650 / - |
MPa MPa MPa |
ISO 527-1/-2 | - | - | - |
|
Tensile Strength X Orientation Y Orientation Z Orientation |
48 / - 48 / - 42 / - |
MPa MPa MPa |
ISO 527-1/-2 | - | - | - |
|
Nominal Strain at Break X Orientation Y Orientation Z Orientation |
18 / - 18 / - 4 / - |
% % % |
ISO 527-1/-2 | - | - | - |
|
Flexural Modulus X Orientation |
1500 / - |
MPa |
ISO 178 | - | - | - |
|
Charpy Impact Strength (+23°C) X Orientation |
53 / - |
kJ/m² |
ISO 179/1eU | - | - | - |
|
Charpy Notched Impact Strength (+23°C) X Orientation |
4.8 / - |
kJ/m² |
ISO 179/1eA | - | - | - |
|
Izod Notched Impact Strength (+23°C) X Orientation |
4.4 / - |
kJ/m² |
ISO 180/1A | - | - | - |
|
Shore D Hardness X Orientation |
75 / - |
- |
ISO 7619-1 | - | - | - |
| THERMAL PROPERTIES | DRY / CONDITIONED | UNIT | TEST STANDARD | DRY / CONDITIONED | UNIT | TEST STANDARD |
|---|---|---|---|---|---|---|
| Melting Temperature | 176 | °C | ISO 11357-1/-3 | - | - | - |
|
Temperature of Deflection under Load 1.80 MPa X Orientation Z Orientation |
64 57 |
°C °C |
ISO 75-1/-2 | - | - | - |
|
Temperature of Deflection under Load 0.45 MPa X Orientation Z Orientation |
157 145 |
°C °C |
ISO 75-1/-2 | - | - | - |
|
Vicat Softening Temperature X Orientation |
176 |
°C |
ISO 306/B50 | - | - | - |
| ELECTRICAL PROPERTIES | DRY / CONDITIONED | UNIT | TEST STANDARD | DRY / CONDITIONED | UNIT | TEST STANDARD |
|---|---|---|---|---|---|---|
|
Comparative Tracking Index CTI X Orientation Y Orientation Z Orientation |
≥600 / - ≥600 / - ≥600 / - |
|
IEC 60112 | - | - | - |
| FIRE PERFORMANCE ELECTRICAL & ELECTRONICS |
RESULT | CONDITION / UNIT | TEST STANDARD |
|---|---|---|---|
| UL 94 Flammability Rating | HB | class | UL 94 |
| Thickness Tested | 0.5 | mm | - |
| UL 94 Flammability Rating | HB | class | UL 94 |
| Thickness Tested | 1.6 | mm | - |
| UL 94 Flammability Rating | HB | class | UL 94 |
| Thickness Tested | 3.2 | mm | - |
| OTHER PROPERTIES | VALUE | UNIT | TEST STANDARD | VALUE | UNIT | TEST STANDARD |
|---|---|---|---|---|---|---|
| Density | 0.93 | g/cm³ | EOS Method | - | - | - |
| Powder Color | white | - | - | - | - | - |
| Components Color | white | - | - | - | - | - |